Skip to content
WolffKran Group · Est. 1854Fast UK delivery & export optionsPrice match promiseCredit accounts for business01709 437141
Prices
Modulift MOD 70H - End Unit
1 / 2

Modulift MOD 70 - End Unit

Part no. MODU-0070-EU035
£1,327.70£1,106.42Inc VATEx VAT
£1,106.42 ex VAT£1,327.70 inc VAT ·

About this item

  • Genuine Modulift MOD 70 end unit
  • Series rated 70t at 10.5m span, up to 14m
  • Two end units required per beam

Product description

The Modulift MOD 70 end unit sits at each end of a MOD 70 spreader beam. Struts bolt to one face and the drop link to the other, so it carries the sling load into the beam and sets the beam's geometry.

It weighs 56 kg and is rated 35 t WLL each (70 t per pair).

Two are needed per beam. The Modulift MOD 70 series is rated 70 t at 10.5 m span (30° sling to vertical), uses matched shackles (55 t top, 35 t lower) and reaches 14 m at reduced capacity.

Key Features
  • Two needed per beam
  • Rated 35 t WLL each (70 t per pair)
  • 56 kg each
  • Matched shackles 55 t top, 35 t lower
  • Genuine Modulift component with certification

Specifications

Part number0070/EU035
SeriesModulift MOD 70
Component typeEnd unit
End unit rating35 t WLL each (70 t per pair)
Weight56 kg
Series rated capacity70 t at 10.5 m span (30° sling to vertical)
Maximum span14 m at reduced capacity
Weight of a complete set at maximum span972 kg
Heaviest single component in the series240 kg
Matched shackles55 t top, 35 t lower
What's Included
  • 1 x Modulift MOD 70 end unit
  • Manufacturer certification

Each end unit takes one of the MOD 70 drop links.

Documents (2)

View on this page or download.

PDFModulift MOD 70 User Instructions
PDF document
PDFModulift Inspection Guide
PDF document

Using and looking after it

Always read the manufacturer’s instructions before use. See the documents

Typical Applications
  • Building a complete MOD 70 beam
  • Replacing a damaged end unit
  • Adding a second beam set
  • Spares for hire fleets

Buying guide

Choosing the Right Size

A beam needs two end units, two drop links and the struts for the span. Use the matched shackle sizes for the series; they are part of the certified geometry.

Questions and answers

Q: How many end units does a beam need?

A: Two, one at each end.

Q: Can I use my own shackles?

A: Use the matched sizes for the series, 55 t top, 35 t lower.

Q: Can I mix end units from different series?

A: No. Use MOD 70 end units with MOD 70 struts and drop links.

Have a question about this product?Ask a question