Pramac MX 15/40 LFP

Pramac MX 15/40 LFP

Part no. PRAMAC-MX-15-40-LFP
£49,350.00£41,125.00Inc VATEx VAT
£41,125.00 ex VAT£49,350.00 inc VAT ·

About this item

  • 15kVA output with 38.4kWh lithium iron phosphate (LFP) battery storage
  • 400/230V three-phase 50Hz supply with UK socket panel fitted
  • MPPT solar input for direct panel charging; silent with no fuel or emissions in use

Product description

The Pramac MX 15/40 LFP brings battery storage to three-phase sites: 15 kVA at 400/230 V from 38.4 kWh of lithium iron phosphate cells. It supplies 400 V distribution boards and plant quietly, with no fuel or exhaust at the point of use.

It gives 32.8 kWh usable energy, a 30 kW peak for motor starting and a 63 A pass-through.

Key Features
  • 15 kVA three-phase, 400/230 V
  • 32.8 kWh usable from 38.4 kWh installed
  • 30 kW peak for 5 seconds
  • 63 A pass-through for hybrid running
  • Compact 1,105 x 1,069 mm footprint

Specifications

ModelMX 15/40 LFP
Continuous output15 kVA
Peak output (5 s)30 kW
Supply400/230 V 50 Hz three phase
Storage capacity38.4 kWh
Usable energy (90% DoD, AC side)32.8 kWh
Battery chemistryLithium iron phosphate (LFP)
Battery modules8 x 4.8 kWh, 48 V DC
Battery weight320 kg
Inverters3 x 5 kVA
Input connections1 x 32 A CEE 3P+N+T (grid), 1 x 63 A CEE 3P+N+T (generator)
Outputs (Pramac standard panel)1 x 16 A CEE 2P+T, 1 x 32 A CEE 2P+T, 1 x 32 A CEE 3P+N+T, 1 x 63 A CEE 3P+N+T; individual RCD on single-phase sockets, common RCD on three-phase
ControlsGSM remote monitoring, automatic generator start signal, inverter protection (short circuit, overload, over-temperature, low battery), battery isolator
OtherStackable 2 high; 50/60 Hz; cold weather kit option
Design life6,000 cycles
Pass-through capacity63 A
ProtectionIP44
Operating temperature-10 to +50 °C
Configuration+HUK (UK socket panel) +MPPT (solar input)
Dimensions (L x W x H)1,105 x 1,069 x 1,737 mm
Weight880 kg
What's Included
  • Pramac MX 15/40 LFP battery energy storage unit
  • UK socket panel (HUK) fitted
  • MPPT solar input fitted
  • Operator and commissioning documentation

Solar panels, generator and site distribution are not included.

You may also need: the Pramac MX 30/60 LFP or the Pramac SX Plus 10/40 LFP if your load or run time differs.

Documents (1)

View on this page or download.

PDFProduct card
PDF document

Using and looking after it

Always read the manufacturer’s instructions before use. See the documents

Typical Applications
  • Three-phase site cabins and distribution
  • Site compounds running through the night
  • Urban sites under noise or air quality conditions
  • Hybrid supply alongside a Stage V generator

Buying guide

Design & Construction

Two figures matter. kVA is the power the unit can deliver at once; kWh is the energy stored, which sets how long it lasts. Usable energy is quoted at 90% depth of discharge (DoD, how far the battery is drained) measured on the AC side, so it allows for inverter losses.

Divide usable kWh by your average load in kW for an estimated run time.

Peak output (30 kW for 5 seconds here) covers the brief surge as motors and compressors start. Pass-through (63 A) is the current a generator or mains supply can feed through the unit to your loads while it recharges the battery.

The cells are lithium iron phosphate (LFP), a lithium chemistry that is more thermally stable and longer lived than standard lithium-ion, with a 6,000-cycle design life. MPPT (maximum power point tracking) is a solar charge controller that gets the most from panels as light changes, so they can charge the battery directly.

On a hybrid site the battery carries the load through quiet periods and the generator runs only to recharge.

Choosing the Right Model

Size on your 24-hour energy use in kWh, not only the peak load. A site drawing 3 kW for 16 hours needs 48 kWh, however small its peak.

Model Output Usable energy Peak (5 s) Phase Pass-through
SX 5/10 5 kVA 8.3 kWh 9 kW Single 32 A
SX 10/15 10 kVA 12.4 kWh 18 kW Single 32 A
SX Plus 5/25 5 kVA 20.5 kWh 10 kW Single 50 A
SX Plus 10/40 10 kVA 33.2 kWh 20 kW Single 80 A
MX 15/40 15 kVA 32.8 kWh 30 kW Three 63 A
MX 30/60 30 kVA 49.8 kWh 60 kW Three 63 A
LX 45/80 45 kVA 66.4 kWh 75 kW Three 100 A
LX 45/100 45 kVA 82.9 kWh 75 kW Three 100 A
LX 60/100 60 kVA 82.9 kWh 120 kW Three 125 A
LX Plus 90/150 90 kVA 124.4 kWh 150 kW Three 200 A

Questions and answers

Q: What can 30 kW peak handle?

A: Short starting surges from motors and compressors, for up to 5 seconds, while the continuous load stays within 15 kVA.

Q: Can it replace a generator entirely?

A: On a light, predictable load with mains or solar to recharge it, yes. On most sites the practical answer is hybrid: the battery plus a smaller generator running a few hours a day.

Q: Does Stage V apply to it?

A: No. Stage V is an engine emissions standard, and the unit has no engine. On hybrid sites, pair it with a Stage V generator.

Have a question about this product?Ask a question

More in Battery Energy Storage Systems