An ATEX radio is a two-way radio that has been certified as safe to use where flammable gas, vapour, mist or combustible dust could form an explosive atmosphere. To choose one, take the zone, gas or dust group and temperature class from the site’s hazardous area classification, then check that the radio’s Ex marking meets or beats all three, along with the ambient temperature range. The battery, speaker-mic and earpiece must be certified for use with that radio, and charging happens outside the zone.
WOLFF Onsite’s site radios include one ATEX-certified handheld, the ATEX Radio, which our product page describes as carrying the highest ATEX gas explosion group rating. We also list a standard Two Way Radio, the Hands Free Tower Crane Radio for crane cabs, audio and carry accessories, and a Voice Recording Solution for logging radio traffic. Only the ATEX Radio is described as certified for hazardous areas. The rest of the range is for ordinary site areas, and this guide is clear about which is which. Our ATEX category also lists ATEX-rated hand chain hoists, pneumatic chain hoists and ratchet lever hoists for lifting in the same areas.
The WOLFF radio range and where each item can go
The table below sets out what each item in our radio range does and whether its product page describes it as certified for hazardous areas. Specifications are taken from the WOLFF product pages, and where a page gives no figure the table says so rather than guessing.
| Product | What it is | Hazardous-area status (per product page) | Stated specifications | Where it belongs |
|---|---|---|---|---|
| ATEX Radio | Handheld two-way radio | ATEX certified; “highest ATEX gas explosion group rating” | Full marking string, category and temperature class not yet listed. Ask us before ordering. | Inside classified gas areas, once the marking has been checked against the zone |
| Two Way Radio | Handheld site radio (walkie-talkie) | Not described as ATEX certified | IP68; battery life up to 28 hours; optional integrated GPS and Bluetooth | General site areas only |
| Hands Free Tower Crane Radio | Digital radio installed in the crane cab with foot pedal and speaker mic | Not described as ATEX certified | Backup battery lasting up to 4 hours; single or double version | Crane cab outside any zone |
| Remote Speaker Microphone | Shoulder or lapel speaker-mic | Not described as ATEX certified | Not stated | With standard radios only |
| D-Shaped Earpiece with Lapel Microphone | Earpiece with inline PTT and lapel mic | Not described as ATEX certified | Not stated | With standard radios only |
| Chest Packs | Universal chest harness for radios | Not described as ATEX certified | Not stated | General site areas. Check the ATEX radio manufacturer’s guidance on carry options before using any carry pack in a zone. |
| Heavy Duty Leather Case | Hard leather belt case | Not described as ATEX certified | For the display range of site radios | With standard display radios |
| Voice Recording Solution | Records and indexes radio traffic | Not described as ATEX certified | 1 to 5 channel options; plug-and-play; encrypted storage | Site office or cabin |
| Body Camera | Hytera SC580 body camera that doubles as a PoC radio | Not described as ATEX certified | HD video; 4G; 3,200mAh battery | General site areas only |
Being honest about the range: WOLFF currently lists one ATEX radio, and no IECEx-only radios. If your classification calls for a dust zone, underground mining or anything else you cannot yet match to our ATEX Radio’s marking, tell us early so we can confirm what we can supply before you commit to a job.
What ATEX means for a radio
“ATEX” comes from the French ATmosphères EXplosibles. It refers to two pieces of European law that work as a pair: one covers the equipment, the other covers the workplace.
The equipment directive: 2014/34/EU
Directive 2014/34/EU, sometimes called ATEX 114, sets the essential health and safety requirements for equipment and protective systems intended for use in potentially explosive atmospheres. It is the manufacturer’s law. It decides how a radio is designed, tested, assessed and marked before it can be sold as ATEX equipment. A radio that meets it carries the CE mark, the Ex hexagon and a marking string giving its equipment group, category and type of atmosphere. For electrical equipment in the higher categories, such as a radio, a notified body must be involved in the assessment, and a notified body’s identification number appears next to the CE mark.
The workplace directive: 1999/92/EC
Directive 1999/92/EC sets minimum requirements for protecting workers who may be at risk from explosive atmospheres. It is the user’s law. It requires the employer to assess the risk, divide hazardous places into zones and make sure that the equipment used in each zone is of a suitable category. The two directives meet at the zone. The workplace directive says which category of equipment a zone needs, and the equipment directive says what that category means.
Great Britain: DSEAR 2002 and UKEX
In Great Britain the workplace side is covered by the Dangerous Substances and Explosive Atmospheres Regulations 2002, known as DSEAR (HSE’s DSEAR guidance). Under DSEAR, employers must assess the risks from dangerous substances, classify places where explosive atmospheres may occur into zones, make sure equipment in those zones is suitable, and mark the entry points to those places with the Ex sign where necessary.
On the equipment side, Great Britain has its own regulations, the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016. The GB version of ATEX marking is usually called UKEX. It uses the UKCA mark with the same Ex marking scheme, and assessment for the higher categories is carried out by a UK approved body. CE-marked ATEX equipment is currently also accepted on the GB market. The government has changed this position more than once, so check current guidance if the marking matters for your contract.
Where IECEx fits
IECEx is an international certification scheme run under the International Electrotechnical Commission. It certifies equipment to the IEC 60079 series of standards, the same technical standards that sit behind most ATEX electrical equipment. An IECEx certificate is widely recognised and useful on international projects, but on its own it is not ATEX or UKEX conformity. For a job in Great Britain or the EU, the ATEX or UKEX marking is what counts.
An IP rating is not an ATEX rating. Our standard Two Way Radio is IP68, which means it resists dust and water. That says nothing about whether it can ignite a flammable atmosphere. Only Ex certification covers that.
Why an ordinary radio is an ignition source
A handheld radio packs a lithium-ion battery, circuit boards, switches and a transmitter into a small case. It is a risk in an explosive atmosphere for several reasons:
- Sparks. Contacts in the push-to-talk switch, the battery terminals and the accessory socket can spark. Unplugging a speaker-mic or swapping a battery is enough to create one.
- Stored energy. A charged battery can release a lot of energy quickly if it is damaged or short-circuited. Some gases, hydrogen in particular, need very little energy to ignite.
- Hot surfaces. Components can run hot during transmission or charging. If any surface goes above the ignition temperature of the gas or dust present, it can ignite it without a spark.
Most ATEX radios use intrinsic safety, the protection concept marked “i”. The circuits are designed so that even under specified fault conditions, the energy in any spark and the temperature of any surface stay below what would ignite the atmosphere. That is why the battery and accessories matter so much. They are part of the circuit that was assessed, and a different battery or speaker-mic changes the energy and temperature limits.
| Intrinsic safety level | Marking | Protection level | Suitable for |
|---|---|---|---|
| Highest | Ex ia | Remains safe with two countable faults | Zones 0, 1 and 2 (and 20, 21, 22 for dust when dust-rated) |
| Middle | Ex ib | Remains safe with one countable fault | Zones 1 and 2 (and 21, 22) |
| Basic | Ex ic | Safe in normal operation | Zone 2 (and 22) |
Hazardous area zones: gas 0/1/2 and dust 20/21/22
A zone describes how likely an explosive atmosphere is to be present and for how long. It does not describe how dangerous the substance is. That is what the gas group and temperature class are for. Gas, vapour and mist zones are numbered 0, 1 and 2, and dust zones 20, 21 and 22.
| Zone | Atmosphere | Definition | Typical examples (for illustration) |
|---|---|---|---|
| Zone 0 | Gas, vapour, mist | An explosive atmosphere is present continuously, for long periods or frequently | Inside a tank or vessel above the liquid surface |
| Zone 1 | Gas, vapour, mist | An explosive atmosphere is likely to occur in normal operation occasionally | Close to vents, sample points, pump seals or filling points |
| Zone 2 | Gas, vapour, mist | An explosive atmosphere is not likely in normal operation, and if it does occur it will persist for a short period only | Around flanges and valves in a well-ventilated plant area |
| Zone 20 | Combustible dust cloud | An explosive dust cloud is present continuously, for long periods or frequently | Inside silos, hoppers and dust extraction ductwork |
| Zone 21 | Combustible dust cloud | A dust cloud is likely to occur in normal operation occasionally | Around bag tipping, filling and emptying points |
| Zone 22 | Combustible dust cloud | A dust cloud is not likely in normal operation, and if it does occur it will persist for a short period only | Rooms near dust handling plant where leaks or layers could be disturbed |
The examples are only to show the idea. Whether a particular place is a zone, and which one, depends on the substance, the release sources, ventilation and housekeeping. That decision belongs to the site’s area classification, not to the radio supplier or the person buying the radio.
Gas groups, temperature classes and equipment categories
Three further parts of the marking tell you which substances and which zones a radio is suitable for. You need all three to match. One that matches does not make up for one that does not.
Equipment groups: I, II and III
Group I is equipment for underground mines and their surface installations that are at risk from firedamp (methane) and coal dust. Under ATEX, Group II covers all other places with explosive atmospheres, gas or dust, and the G or D after the category says which. In the IEC 60079 scheme, gas equipment is Group II and dust equipment is Group III. A radio for a refinery, a chemical plant or a wastewater site is Group II, and one for coal mining is Group I. One does not stand in for the other.
Gas groups: IIA, IIB and IIC
Group II gases are subdivided by how easily they ignite and how readily a flame passes through a narrow gap. IIA is the least demanding and IIC the most. Equipment certified for a higher group is also suitable for the lower ones. A IIC radio can be used for IIB and IIA gases, but a IIA radio cannot be used where IIB or IIC gases are present.
| Gas group | Representative gas | Other examples | Covered by equipment marked |
|---|---|---|---|
| IIA | Propane | Methane (above ground), butane, petrol vapour | IIA, IIB or IIC |
| IIB | Ethylene | Many industrial solvents and process gases | IIB or IIC |
| IIC | Hydrogen | Acetylene, carbon disulphide | IIC only |
For dust, the equivalent groups are IIIA (combustible flyings, such as fibres), IIIB (non-conductive dust) and IIIC (conductive dust, such as some metal dusts). IIIC is the most demanding and covers the other two.
The WOLFF ATEX Radio product page describes it as having the highest ATEX gas explosion group rating. The highest gas group is IIC, which covers hydrogen and acetylene as well as IIA and IIB gases. Ask us for the full marking to confirm this, along with the temperature class and category.
Temperature classes: T1 to T6
Every flammable gas has an auto-ignition temperature, the temperature at which a hot surface will ignite it without a spark. A temperature class sets the maximum surface temperature the equipment can reach. The equipment’s class must stay below the ignition temperature of every gas that could be present. The higher the T number, the cooler the equipment runs, and a higher class covers all the lower ones.
| Temperature class | Maximum surface temperature | Also suitable where the requirement is |
|---|---|---|
| T1 | 450°C | T1 |
| T2 | 300°C | T1, T2 |
| T3 | 200°C | T1 to T3 |
| T4 | 135°C | T1 to T4 |
| T5 | 100°C | T1 to T5 |
| T6 | 85°C | T1 to T6 |
Gas group and temperature class are separate properties. Hydrogen is IIC but ignites only at a high surface temperature, so it is T1. Carbon disulphide is also IIC but ignites at a very low surface temperature, so it needs T6. A radio marked IIC T4 is fine for hydrogen but not for carbon disulphide. That is why you check both.
Dust-rated equipment shows its actual maximum surface temperature in degrees, such as T135°C, rather than a T class. The installation rules apply safety margins below both the dust cloud and dust layer ignition temperatures. Thick layers lower the safe figure further, so whoever does the classification should confirm the allowable surface temperature.
Equipment categories 1, 2 and 3, and protection levels
The category, which appears in the ATEX part of the marking, states the level of protection. Under DSEAR and the workplace directive, each zone has a minimum category. The IEC scheme expresses the same idea as an Equipment Protection Level (EPL), which you will see at the end of most marking strings.
| ATEX category | EPL (gas / dust) | Level of protection | Permitted zones |
|---|---|---|---|
| Category 1 (1G / 1D) | Ga / Da | Very high. Safe even with rare faults. | Gas zones 0, 1, 2 / dust zones 20, 21, 22 |
| Category 2 (2G / 2D) | Gb / Db | High. Safe with expected faults. | Gas zones 1, 2 / dust zones 21, 22 |
| Category 3 (3G / 3D) | Gc / Dc | Normal. Safe in normal operation. | Gas zone 2 / dust zone 22 |
| M1 / M2 (Group I) | Ma / Mb | Mining categories | Underground mines at risk from firedamp or coal dust |
The letter after the category number matters. G means gas, vapour or mist and D means dust. A radio marked only 2G is not certified for dust zones, however clean the dust looks.
How to read a marking string
The marking string is printed on the radio’s label, often inside the battery compartment, and repeated on the certificate and in the manual. Our ATEX Radio product page does not yet list its full marking, so the example below is an illustrative marking of a kind commonly seen on intrinsically safe handheld radios. It is not the marking of a specific WOLFF product. Ask us for the actual marking and certificate of the radio you are considering, and check it line by line against this table.
Illustrative example: CE 0000 ⬡Ex II 2G Ex ib IIC T4 Gb Ta = −20°C to +50°C
| Part | Meaning | What to check |
|---|---|---|
| CE 0000 (or UKCA with an approved body number) | Conformity mark and the number of the notified or approved body involved. 0000 here is a placeholder. | That the mark suits the market you are working in, and that a certificate exists to match it |
| Ex hexagon | The specific mark for explosion-protected equipment | That it is present. Without it, the item is not ATEX equipment. |
| II | Equipment group: non-mining | Group I is needed for underground mining instead |
| 2G | Category 2, gas atmospheres | Category 2 permits zones 1 and 2. Zone 0 needs category 1. There is no D, so no dust zones. |
| Ex ib | Protection concept: intrinsic safety, level “b” | Consistent with zone 1 use. Ex ia would be needed for zone 0. |
| IIC | Gas group | Covers IIA, IIB and IIC gases |
| T4 | Temperature class: max surface temperature 135°C | Below the auto-ignition temperature of every gas present; the site will state the class it needs |
| Gb | Equipment Protection Level for gas | Matches the zone: Ga for zone 0, Gb for zone 1, Gc for zone 2 |
| Ta = −20°C to +50°C | Ambient temperature range the certification covers | That the work area stays within it. If no range is marked, the standard range of −20°C to +40°C applies. |
A certificate number ending in X means there are specific conditions of use. For a radio, these often cover which batteries and accessories can be fitted, how the radio is carried, or a warning about static on the case.
Read the battery label too. If the battery part number is not on the radio’s approved list, the combination is not certified, even if both items look identical to the standard version.
Matching the radio to the zone: a five-step check
This is the sequence we suggest for any job where radios will go into a classified area. Each step is a yes or no. If any answer is no, that radio does not go into that zone.
- Get the classification in writing. Ask for the hazardous area drawing or zone schedule, the substances involved, their gas or dust groups and the temperature class required.
- Check the category and EPL against the worst zone. List every zone the radio user will enter, including transits through a zone to reach the work face. Zone 0 needs category 1 / Ga, zone 1 needs category 2 / Gb or better, and zone 2 needs category 3 / Gc or better. Dust zones follow the same pattern with D and Da/Db/Dc.
- Check the group. Gas group on the radio equal to or higher than the highest group on the schedule (IIC beats IIB beats IIA). Dust group IIIC beats IIIB beats IIIA. Group I for mining only.
- Check the temperature. T class on the radio equal to or higher in number than required (T6 beats T4 beats T3). For dust, the stated surface temperature must be below the limit the classification sets.
- Check the ambient range and the accessories. Make sure the work area stays within the marked Ta range, and that every battery, speaker-mic, earpiece and carry item the user will have is listed as approved for that radio.
Worked number check
Suppose a schedule calls for Zone 1, IIB, T3, and you are offered a radio marked II 2G Ex ib IIC T4 Gb.
- Zone: category 2G / Gb is permitted in zone 1. Pass.
- Group: IIC is higher than IIB, so it covers it. Pass.
- Temperature: T4 means a maximum of 135°C, which is cooler than the 200°C allowed by T3. Pass.
Now change the schedule to Zone 0, IIA, T3. The same radio fails at step two, because zone 0 needs category 1 / Ga and the radio is 2G / Gb.
Certified accessories, batteries and charging
This is where ATEX radio set-ups often go wrong on site: the radio is certified, but the kit attached to it is not.
Batteries
The battery is part of the intrinsically safe system. Only batteries listed on the radio’s certificate or in the manufacturer’s instructions may be used, and a standard battery for a similar-looking non-ATEX model is not a substitute. Manufacturers’ instructions for ATEX radios normally say that batteries must not be fitted, removed or swapped inside the hazardous area, because the terminals can spark as they make and break.
Speaker-mics and earpieces
A speaker-mic or earpiece connects to the radio’s circuits, so it must be certified for use with that specific radio. Our Remote Speaker Microphone and D-Shaped Earpiece with Lapel Microphone suit slingers and banksmen on general site areas, but their product pages do not describe them as ATEX certified, so they must not be used with the ATEX Radio inside a zone. If a hazardous-area user needs hands-free audio, ask us for a certified accessory for the ATEX Radio. Do not adapt a standard one. Plugging or unplugging an accessory in the zone is also a spark risk, so connect it before entry.
Cases, pouches and chest packs
Carry items are not electrical, but some plastic or synthetic materials can build up static. The radio’s instructions or the certificate’s specific conditions of use may say which cases are approved or warn against rubbing the case. Our Chest Packs and Heavy Duty Leather Case are designed for the standard range. Check the ATEX radio’s instructions before using any carry item in a zone, and follow what they say.
Charging
Chargers for ATEX radios are generally not ATEX equipment themselves. They are designed to be used in a safe area, and charging produces heat and makes and breaks contacts. Set up the charging station in a cabin, office or other non-classified area, and make it part of the site routine that radios are charged and fully clipped together before anyone enters a zone. Our standard Two Way Radio hire package includes a spare battery and charger. For the ATEX Radio, ask us to confirm the approved battery and charger before you plan your charging rota.
One rule for the whole crew: clip the radio, battery and accessory together outside the zone, and do not open, swap or charge anything until you are back outside.
Where construction and lifting crews meet hazardous areas
Most building sites never need an ATEX radio. Crews meet hazardous areas when they work on or next to live process plant, or when the project itself creates one. Typical situations include:
- Refinery, petrochemical and chemical plant projects, including shutdowns and turnarounds where tie-ins are made to live systems
- Fuel depots, forecourts and fuel storage installations
- Wastewater treatment works, sludge digesters and biogas plant, where methane may be present
- Gas distribution and gas holder sites
- Food, grain, flour, timber and powder processing plants, where combustible dust may form clouds
- Battery rooms and hydrogen installations, including some energy storage and charging installations
- Confined spaces with potential for flammable gas, which also need a confined space risk assessment and gas monitoring
Lifting is a common reason for construction crews to enter these areas. The crane may stand outside the classified area while the slinger and signaller work inside it, or a hoist may be rigged inside a process building. Every item taken into the zone must be suitable for it, not just the radio. Our ATEX category lists ATEX-rated hoists for this reason, and our guides to pneumatic and electric hoists and chain blocks and lever hoists explain how those hoist types differ. For crane-to-ground communication generally, including channel planning and hands-free options, see our sibling guide to two-way radios for construction sites.
A practical point for mixed sites: the crane operator, in the cab outside the zone, can use the Hands Free Tower Crane Radio and a standard radio. The slinger inside the zone uses the ATEX Radio. Both radios must be able to work on the same channel, so check compatibility at the planning stage, not on the morning of the lift.
Four example scenarios, worked through
The examples below are typical scenarios, not records of particular jobs. The zone, group and temperature class in each are assumptions for illustration. On a real job, use the figures in the site’s classification.
1. Steel erection next to a live refinery unit
A steel erection crew is placing pipe-rack sections beside a live unit. The permit shows that the slinging area sits in a Zone 2 with a schedule of IIB, T3, and the crane stands outside the classified area. The slinger and signaller need radios that are at least category 3G / Gc, IIB or IIC, and T3 or higher. The ATEX Radio would be the candidate, subject to checking its full marking against the schedule. The crane operator stays on the cab system outside the zone. Earpieces and speaker-mics stay off the slinger’s radio unless certified accessories for it are supplied.
2. Pipework tie-in inside a process building
A mechanical contractor is lifting valves with a chain hoist inside a building classified as Zone 1, with a hydrogen-containing process stream, so the schedule is IIC, T1. The radio needs to be category 2G / Gb or better and group IIC. Any T class satisfies T1, but the group is the deciding point: a IIB radio fails. The hoist must also be suitable for the zone, so see our ATEX hand chain hoists and ATEX lever hoists categories.
3. Steelwork alterations in a flour mill
A team is modifying a mezzanine in a flour mill, and the area by the bagging line is classified as Zone 22. This is a dust zone, so the radio needs a dust rating: category 3D / Dc or better, a suitable dust group (flour is non-conductive, so IIIB, which IIIC also covers), and a surface temperature below the limit set by the classification. A radio marked only for gas, however high its gas group, is not certified here. If the radio you are offered has no D or Group III line on its marking, it should not be used.
4. Digester repairs at a wastewater treatment works
Repair work around a sludge digester has a Zone 1 near the gas handling equipment and a Zone 2 around it, with methane as the main flammable gas. Methane is IIA, T1. Anyone working in the Zone 1 area needs category 2G / Gb or better, and a IIC radio covers IIA. The standard radios and the body camera stay with the team outside the classified area.
Safety and UK rules that apply
This is a summary to help you ask the right questions. It is not legal advice, and the site’s own risk assessment and permit system take priority.
- DSEAR 2002 puts the duty on the employer: assess the risk from dangerous substances, classify zones, choose suitable equipment and mark zone entry points with the Ex sign where necessary. Contractors working on a client’s plant should expect to receive the classification and to follow the client’s permit-to-work system.
- Equipment marking in Great Britain falls under the 2016 equipment regulations (UKEX). CE-marked ATEX equipment is currently accepted too. Check the current position if your contract specifies a mark.
- Competence. Selecting, inspecting and maintaining Ex equipment is a specialist field. Clients on major hazard sites often require Ex-trained people to inspect equipment before it enters a zone.
- Inspection and repair. Do not repair, open or modify an ATEX radio on site. A cracked case, damaged battery contacts or a missing label can invalidate the certification. Take the radio out of use and return it.
- Lifting law still applies. LOLER 1998 and PUWER 1998 apply to lifting operations and work equipment in hazardous areas just as they do anywhere else. Our tower crane lifting equipment guide covers the lifting side.
- Radio licensing. Business radios generally need an Ofcom licence for the frequencies they use. Our standard Two Way Radio hire package states that it includes one. Ask us about licensing for the ATEX Radio when you order.
Common mistakes
- Treating IP68 as explosion protection. A waterproof, dustproof radio can still ignite gas. Look for the Ex hexagon and a marking string, not an IP number.
- Checking the zone but not the group or temperature. A category 2 radio rated IIA cannot be used in a IIC area. All three must match.
- Assuming a gas rating covers dust. G and D are separate. A gas-only radio is not certified for dust zones.
- Fitting a standard battery. It may look the same and fit the same, but if it is not on the certificate, the radio is no longer certified.
- Adding a non-certified earpiece or speaker-mic. It is an easy way to compromise an ATEX radio on a lifting job, because slingers want hands-free audio.
- Swapping batteries or charging in the zone. Battery changes and charging belong in the safe area.
- Ignoring the ambient range. Hot process areas in summer, or cold early starts, can fall outside the marked Ta range.
- Forgetting the walk-through. Users often transit a higher-risk zone to reach a lower-risk work face. The radio must suit the worst zone on the route.
- Missing the “X” on the certificate. Specific conditions of use are part of the certification. If nobody reads them, nobody follows them.
From the WOLFF team
These examples come from real enquiries, quotes and orders we have handled. Customer details are left out.
Zone and gas group first, product second
Our ATEX enquiries come mostly for hoists rather than radios, but the lessons apply to any ATEX equipment. One overseas chemical customer specified either Class I Division 1 or ATEX Zone 1/2 with gas group IIB. The quickest available build was ATEX Category 3: Zone 2, gas group IIA. That is likely to suit their solvent, but it met neither option in full. We quoted it with that clearly stated and asked them to confirm the zone before ordering. Another customer asked for Zone 0. We told them plainly that we weren't aware of a hoist certified for Zone 0, and asked where the equipment would actually sit. Getting the zone and gas group confirmed in writing first avoids certified equipment being rejected on arrival.
If you send us your zone schedule, we will check it against the ATEX Radio’s marking and tell you clearly whether it fits. If it does not, we will tell you that too.
Frequently asked questions
What is an ATEX radio?
An ATEX radio is a two-way radio certified under the ATEX equipment directive 2014/34/EU, or the GB equivalent, as safe to use in a potentially explosive atmosphere. It carries the Ex hexagon and a marking string giving its group, category, protection concept, gas or dust group and temperature class. Most use intrinsic safety, which limits spark energy and surface temperature so the radio cannot ignite the atmosphere.
Is an IECEx radio the same as an ATEX radio?
Not legally. IECEx is an international certification scheme based on the IEC 60079 standards, and many radios hold both IECEx and ATEX certificates. For use in Great Britain or the EU you need ATEX or UKEX conformity. An IECEx certificate on its own does not provide that, although it is useful on international projects.
Can I use an ATEX radio in Zone 0?
Only if it is category 1G with EPL Ga, which usually means intrinsic safety level “ia”. Many handheld ATEX radios are category 2G / Gb, which permits zones 1 and 2 but not zone 0. Check the marking on the radio you are offered, not the general description.
Can I use a normal earpiece or speaker-mic with an ATEX radio?
No. Accessories connect to the radio’s circuits and must be certified for use with that specific radio. A standard earpiece or speaker-mic, such as those in our general radio range, can invalidate the radio’s certification in a zone.
Can I change or charge the battery inside the hazardous area?
You should assume not. Manufacturers’ instructions for ATEX radios normally say that batteries must be changed and charged outside the hazardous area, and chargers are generally designed for use in safe areas. Follow the instructions for the specific radio.
Is an ATEX radio suitable for dust zones?
Only if its marking includes a dust rating: a D category (such as 2D or 3D) or a Group III marking with a Db or Dc protection level and a stated surface temperature. A gas-only rating does not cover dust. Our ATEX Radio’s product page does not state a dust rating, so ask us before planning dust zone work.
Who decides which zone an area is?
The employer or site operator, as part of their DSEAR risk assessment and area classification. As a contractor or radio user, ask for the hazardous area drawing or zone schedule and select equipment to meet it.
Does WOLFF offer more than one ATEX radio?
At the moment our radio range lists one ATEX-certified handheld, the ATEX Radio. Our other radios and accessories are for general site areas. Send us your zone schedule and we will confirm whether the ATEX Radio’s marking covers it.
Where next
- Browse all site radios and the wider construction site radio equipment category
- View the WOLFF ATEX Radio, and compare it with the standard Two Way Radio
- Other ATEX kit: ATEX equipment, including hand chain hoists, pneumatic chain hoists and ratchet lever hoists
- Accessories for general site areas: remote speaker microphone, D-shaped earpiece, chest packs and heavy duty leather case
- Crane communication: Hands Free Tower Crane Radio and Voice Recording Solution
- Related guides: Two-way radios for construction sites, Pneumatic (air) hoists vs electric, Crane camera systems, Wind speed limits for tower crane operations, Rescue and stretcher cages and Lifting people by crane
- Hiring rather than buying? See our equipment hire page and the benefits of online equipment hire
Send us your zone schedule, gas or dust group and temperature class, and we will check them against our ATEX Radio’s marking. Email hello@wolffonsite.co.uk, call 01709 437141, or contact our team.